Space requirements

The Small Office Edition is designed to be free-standing or wall mounted. The base includes integral screw-head slots for wall mounting and an additional bracket is supplied with the module for a locking screw.

All the other IP Office control units and modules are designed to be installed either in a free-standing stack or into a 19" rack system. Rack installation requires a rack mounting kit for each control unit and expansion module.

 

Cable Clearance
Clearance must be provided at the front and rear of all modules for cable access and feature key dongle connection.
On IP400 and Small Office Edition systems, allow a minimum clearance of 75mm (3 inches).
On IP500 systems allow a minimum clearance of 90mm (3.5 inches).
Additional Clearance
Care should be taken to ensure that the positioning of the modules does not interrupt air flow and other factors that may affect environmental requirements.  This is especially important on IP500 control units which have ventilation slots at the side.
Cable Access
Power cords must not be attached to the building surface or run through walls, ceilings, floors and similar openings. Installation measures must be taken to prevent physical damage to the power supply cord, including proper routing of the power supply cord and provision of a socket outlet near the fixed equipment or positioning of the equipment near a socket outlet.

 

Small Office Edition Control Unit

The Small Office Edition control unit can be used free-standing or wall mounted.

size soe

 

IP400 Control Units and External Expansion Modules

size

 

IP500 Control Unit

When wall mounted, a clearance of 500mm is required on all sides. The ventilation slots on the rear and sides should not be covered or blocked.

ip500size

 

 

© 2009 AVAYA
15-601042 Issue 20.i.-
10:12, 18 November 2009
(spacerequirements.htm)

Performance figures, data and operation quoted in this document are typical and must be specifically confirmed in writing by Avaya before they become applicable to any particular order or contract. The company reserves the right to make alterations or amendments at its own discretion. The publication of information in this document does not imply freedom from patent or any other protective rights of Avaya or others. All trademarks identified by (R) or TM are registered trademarks or trademarks respectively of Avaya Inc. All other trademarks are the property of their respective owners.

Last Modified: 14/12/2007